How to Configure a DEC EtherWORKS II Turbo NIC


The DEC EtherWORKS II Turbo NICs are half-size 16-bit ISA cards based on the AMD 7990 LANCE Ethernet Controller. They come in 3 variants: The DE200 and DE202 both have a DIP shunt which controls which connector will be used for the Ethernet connection. Each of the boards has a 12 pin DIP switch which has the same meaning for all EtherWORKS II Turbo NICs. The rest of this page documents those switch settings.

Default Settings

The default settings for the EtherWORKS II Turbo NICs are: With these settings, the 12 pin DIP switch looks like:

Closed/ON
1 2 3 4 5 6 7 8 9 10 11 12
O




O
O


O


O


O




O
O




O


O


O


O
Open/OFF

In the tables that follow, the default settings are distinguished thusly.


Detailed Switch Settings

Setting the Memory Window

Memory Window Switch Settings
Address Range Size SW1 SW2 SW3 SW4
C0000 .. CFFFF 64KB ON ON ON ON
C8000 .. CFFFF 32KB ON ON off off
D0000 .. DFFFF 64KB ON off ON ON
D8000 .. DFFFF 32KB ON off off off
E0000 .. EFFFF 64KB off ON ON ON
E8000 .. EFFFF 32KB off ON off off
Invalid Switch
Settings
(Do Not Use These)
off off
ON off
off ON

Setting the I/O Address and Remote Boot Options

I/O Address and Remote Boot Switch Settings
Swith Setting Description
SW5 off Sets I/O Range to 200-20F (hex)
ON Sets I/O Range to 300-30F (hex)
SW6 off Enables Remote Boot
ON Disables Remote Boot
SW7 off Selects Remote Boot Timeout of 30 seconds
ON Select Remotes Boot Timeout of 150 seconds

Setting the IRQ

IRQ Switch Settings
Switch IRQ 5 IRQ 9 IRQ 10 IRQ 11 IRQ 12
SW8 ON off off off off
SW9 off ON off off off
SW10 off off ON off off
SW11 off off off ON off
SW12 off off off off ON